Features

  • Devices are ANSI A156.3 - 2008 Grade 1
  • UL Fire and Panic listed                                                                                                      Note: Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Sargent Manufacturing Company makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.
  • Latchbolt adjustable to allow for 1/8" (3mm) - 3/8" (9mm) door gap centerline of bevel
  • Top case latchbolt projection adjustable through center case
  • Tripping potential removed - no bottom strike
  • All functions determined by outside trim
  • Concealed rods for security and aesthetics
  • Patented design – U.S. Patent No. 6,174,004

Specifications

  • Door Types: Factory prepped wood/metal doors for surface mounted SP8600 devices 1-3/4"(44mm) doors only with 2-3/4" (70mm) backset 4-1/2" (114mm) minimum stile (584 Kit required for wood doors)
  • Door Widths:
    E Rail - 24" to 32" No cutting required for 32" door;
    F Rail - 33" to 36"  No cutting required for 36" door;
    J Rail - 37" to 42"  No cutting required for 42" door;
    G Rail - 43" to 48"  No cutting required for 48" door
  • Strike: 650 Top Strike & C7710 Mortise Strike (Panic & Fire Rated)
  • Dogging Feature: Hex key dogging standard; Cylinder dogging available (16-)
  • Electric Options: AL-alarm, PL-SARGuide photoluminescent coated, BT-Beacon, TL-SARGuide illuminated touchpad, 54-Outside lever monitoring, 55-Request-to-exit signal-Rail monitoring, 56-ELR remote latch retraction, 57- Delay egress & electromagnets 58-Electric dogging 
  • Mounting Fasteners: Supplied standard machine screws
  • Top bolt: Stainless Steel
  • Device Centerline from Finished Floor: 41” (1041 mm) for standard applications
  • Door/Opening Height: Must be specified - 120" (3048mm) Max Door Opening
  • Center Case Dimensions: 8-3/8" (213mm) x 2-5/8" (67mm)
  • Projection: Pushbar Neutral – 3" (76 mm); Pushbar Depressed – 2-1/8" (54 mm)

Ideally suited for

  • Hospitals
  • Schools
  • Cross Corridor Doors

 Schools  Healthcare  Commercial 

 

ASSA ABLOY, the global leader in door opening solutions

Copyright © 2004—2014 SARGENT Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.

Reproduction in whole or in part without the express permission of SARGENT Manufacturing Company is prohibited.

Policies  |  This site was designed by NewCity